227 research outputs found

    Digital receiver study and implementation

    Get PDF
    Computer software was developed which makes it possible to use any general purpose computer with A/D conversion capability as a PSK receiver for low data rate telemetry processing. Carrier tracking, bit synchronization, and matched filter detection are all performed digitally. To aid in the implementation of optimum computer processors, a study of general digital processing techniques was performed which emphasized various techniques for digitizing general analog systems. In particular, the phase-locked loop was extensively analyzed as a typical non-linear communication element. Bayesian estimation techniques for PSK demodulation were studied. A hardware implementation of the digital Costas loop was developed

    Task ll Report, Part 2: Evaluation of Water Supplies in the Red River, Dix River, and Mainstem Watersheds of the Kentucky River

    Get PDF
    This study was part of a larger study of water supplies throughout the Kentucky River Basin conducted by the Kentucky Water Resources Research Institute for the Kentucky River Authority. This report examines municipal and private water supplies in the Red River, Dix River, and mainstem Kentucky River watersheds. Municipal supplies which depend on the mainstem Kentucky River, and municipal and private supplies in the North, South, and Middle Fork watersheds of the Kentucky River basin are examined in separate reports

    Electron-ion recombination of Si IV forming Si III: Storage-ring measurement and multiconfiguration Dirac-Fock calculations

    Get PDF
    The electron-ion recombination rate coefficient for Si IV forming Si III was measured at the heavy-ion storage-ring TSR. The experimental electron-ion collision energy range of 0-186 eV encompassed the 2p(6) nl n'l' dielectronic recombination (DR) resonances associated with 3s to nl core excitations, 2s 2p(6) 3s nl n'l' resonances associated with 2s to nl (n=3,4) core excitations, and 2p(5) 3s nl n'l' resonances associated with 2p to nl (n=3,...,infinity) core excitations. The experimental DR results are compared with theoretical calculations using the multiconfiguration Dirac-Fock (MCDF) method for DR via the 3s to 3p n'l' and 3s to 3d n'l' (both n'=3,...,6) and 2p(5) 3s 3l n'l' (n'=3,4) capture channels. Finally, the experimental and theoretical plasma DR rate coefficients for Si IV forming Si III are derived and compared with previously available results.Comment: 13 pages, 9 figures, 3 tables. Accepted for publication in Physical Review

    Multicenter flow cytometry proficiency testing of canine blood and lymph node samples

    Get PDF
    Background: Flow cytometry (FC) is used increasingly in veterinary medicine for further characterization of hematolymphoid cells. Guidelines for optimizing assay performance and interpretation of results are limited, and concordance of results across laboratories is unknown. Objectives: This study aimed to determine inter-investigator agreement on the interpretation of FC results from split samples analyzed in different laboratories using various protocols, cytometers, and software; and on the interpretation of archived FC standard (FCS) data files contributed by the different investigators. Methods: This was a multicenter observational cross-sectional study. Anticoagulated blood or lymph node aspirate samples from nine client-owned dogs were aliquoted and shipped to participating laboratories. Samples were analyzed with individual laboratory-developed protocols. In addition, FCS files from a set of separate samples from 11 client-owned dogs were analyzed by participating investigators. A person not associated with the study tabulated the results and interpretations. Agreement of interpretations was assessed with Fleiss\u2019 kappa statistic. Results: Prolonged transit times affected sample quality for some laboratories. Overall agreement among investigators regarding the FC sample interpretation was strong (\u3ba = 0.86 \ub1 0.19, P <.001), and for specific categories, ranged from moderate to perfect. Agreement of the lymphoproliferation or other leukocyte sample category from the analysis of the FCS files was weak (\u3ba = 0.58 \ub1 0.05, P <.001). Conclusions: Lymphoproliferations were readily identified by FC, but identification of the categories of hematolymphoid neoplasia in fresh samples or archived files was variable. There is a need for a more standardized approach to maximize the enormous potential of FC in veterinary medicine

    Tetragonal magnetostriction and magnetoelastic coupling in Fe-Al, Fe-Ga, Fe-Ge, Fe-Si, Fe-Ga-Al, and Fe-Ga-Ge alloys

    Get PDF
    This paper presents a comparative study on the tetragonal magnetostriction constant,λγ,2, [ = (3/2)λ100] and magnetoelastic coupling, b1, of binary Fe100-xZx (0 \u3c x \u3c 35, Z = Al, Ga, Ge, and Si) and ternary Fe-Ga-Al and Fe-Ga-Ge alloys. The quantities are corrected for magnetostrains due to sample geometry (the magnetostrictive form effect). Recently published elastic constant data along with magnetization measurements at both room temperature and 77 K make these corrections possible. The form effect correction lowers the magnetostriction by ∼10 ppm for high-modulus alloys and by as much as 30 ppm for low-modulus alloys. The elastic constants are also used to determine the values of the magnetoelastic coupling constant, b1. With the new magnetostriction data on the Fe-Al-Ga alloy, it is possible to show how the double peak magnetostriction feature of the binary Fe-Ga alloy flows into the single peak binary Fe-Al alloy. The corrected magnetostriction and magnetoelastic coupling data for the various alloys are also compared using the electron-per-atom ratio, e/a, as the common variable. The Hume-Rothery rules link thee/a ratio to the regions of phase stability, which appear to be intimately related to the magnetostriction versus the solute concentration curve in these alloys. Using e/a as the abscissa tends to align the peaks in the magnetostriction and magnetoelastic coupling for the Fe-Ga, Fe-Ge, Fe-Al, Fe-Ga-Al, and Fe-Ga-Ge alloys, but not for the Fe-Si alloys for which the larger atomic size difference may play a greater role in phase stabilization. Corrections for the form effect are also presented for the rhombohedral magnetostriction,λɛ,2, and the magnetoelastic coupling, b2, of Fe100-xGax (0 \u3c x \u3c 35) alloys

    Rhombohedral magnetostriction in dilute iron (Co) alloys

    Get PDF
    Iron is a well-utilized material in structural and magnetic applications. This does not mean, however, that it is well understood, especially in the field of magnetostriction. In particular, the rhombohedral magnetostriction of iron, λ111 , is anomalous in two respects: it is negative in sign, in disagreement with the prediction of first principles theory, and its magnitude decreases with increasing temperature much too rapidly to be explained by a power law dependence on magnetization. These behaviors could arise from the location of the Fermi level, which leaves a small region of the majority 3d t2g states unfilled, possibly favoring small internal displacements that split these states. If this view is correct, adding small amounts of Co to Fe fills some of these states, and the value of λ111 should increase toward a positive value, as predicted for perfect bcc Fe. We have measured the magnetostriction coefficients (λ111 and λ100) of pure Fe, Fe97Co3, and Fe94Co6 single crystals from 77 K to 450 K. Resonant ultrasound spectroscopy has been used to check for anomalies in the associated elastic constants, c 44 and c′. The additional electrons provided by the cobalt atoms indeed produced positive contributions to bothmagnetostriction constants, λ111 and λ100, exhibiting an increase of 2.8 × 10−6 per at. % Co for λ111 and 3.8 × 10−6 per at. % Co for λ100
    • …
    corecore